Electrical wiring in a bathhouse - diagram and correct installation, methods and standards for laying cables. Carrying out communications in a bathhouse Communications how to plan during the construction of a bathhouse

There is hardly a person who does not dream of own bathhouse on the site. And even more so, it will be great if you build such a bathhouse with your own hands. Isn't it a dream for a man? In addition to the nuances of construction, which, perhaps, have long been studied and taken into account, it is worth paying attention to the various communications for the bathhouse. A bathhouse, the communications for which have been thought out from the very beginning, will bring pleasure to the owners for many years and will be able to become acquainted with future generations of the family. What exactly is important to pay attention to:
Ventilation;
Wiring;
Sewerage;
Supply of cold and hot water (water supply).
If the water is to be heated using gas equipment, it is necessary to take care of laying the gas pipeline. The easiest way to carry out communications for a bathhouse is if there is a house next to it, in which everything necessary is already provided. The installation of sewerage, water supply, and, when choosing gas heating of water, a gas pipeline, must be thought out at the construction stage.

Sewerage – essential element the entire communication cycle for the bathhouse. In our case, we are no longer talking about waste disposal, but about draining water. There are few options here:
Regular cesspool;
Septic tank;
Connection to common system sewerage.
Connecting the bathhouse sewerage system to the general system can be done with your own hands if you have special knowledge and experience. If there are none, it is better to call a team of craftsmen and pay.


A septic tank is a kind of reservoir located underground. Can be single-chamber or multi-chamber. You can install a single-chamber septic tank with your own hands, but you will need to regularly invite special machines to pump out the contents. And access to the septic tank must be unhindered. A multi-chamber septic tank is much easier to operate, but you won’t be able to install it yourself without special skills.
Important to remember! Installing a septic tank is not recommended in places where the groundwater level exceeds 2 meters.
A cesspool or sump well does not need any special introduction. This is an ordinary well, which is dug at a distance from the bathhouse. The water there can be treated by some kind of bacteria, absorbed into the ground or poured into other wells, from where it will “go” into a drain - a ditch, for example.
Whatever sewage system is chosen, in the room where the water is drained, a drain ladder is installed in the floor, which is equipped with a water seal - a device that will prevent debris from entering the sewer, and also will not allow odors from the pipe to “spill” throughout the bathhouse.

How will we supply water?

Water can be supplied to the bathhouse in the following ways:
Submission from centralized system;
Autonomous water supply system (well);
Well.
In suburban villages, the water supply from a centralized system can be unstable, so many people prefer independent water supply systems. Water supply from a well or borehole must be carried out using a pump. At the same time, it is important to evaluate the quality of the electrical network - if the power is often cut off, it is worth buying a generator.
Pipes to the bathhouse for water supply are installed depending on the planned time of using the bathhouse - if all year round, then it is advisable to lay the pipeline underground. Next, a pump, a check valve, a pressure switch and a hydraulic accumulator are connected to the pipes. A pumping station can simplify the task. Now comes the time to organize the supply of hot water. There are only two choices - electric heaters or a gas boiler. For the latter, you will need to install a gas pipeline to the bathhouse and involve specialists, but it will allow you to save on electricity.

Let there be light!

Electricity in a bathhouse is a separate topic that requires a careful, thoughtful approach, because a bathhouse is built of wood, and electrical wiring is an excellent fire provocateur. In addition, the steam room has aggressive temperature conditions. Electrical wiring in a bathhouse can be hidden or open. Carry out installation hidden wiring it will be more expensive and more difficult. Open wiring mounted in a corrugated pipe. Using special brackets, the wiring is attached to the walls.
In each room you need to provide a type of lampshade. So, for example, you should not hang plastic lampshades in the steam room; it is better to give preference to glass lampshades with metal body. No sockets or switches can be installed here.

What about the air?

It would seem that what kind of ventilation can we talk about if we go to the bathhouse precisely for this - concentrated hot humid air. However, humid air is not very friendly to bathhouse surfaces, especially wooden ones. And they are the majority there. To avoid mold and other troubles, the steam room and dressing room should always be at the optimal humidity level. How to achieve this?
The scheme of future ventilation is very simple: only 2 holes are required - for the supply of fresh air and the outflow of humid air. Let's remember physics: warm air always rises, which means that in order for fresh air to enter, it is necessary to make a hole at the bottom. Experts recommend making a window as close to the stove as possible.
The window for air outflow should be made according to the opposite principle - at the top of the steam room, and preferably in the exact place where the temperature is maximum.
You can think through the ventilation in the dressing room according to the same scheme, only the windows for air can be smaller.
By following all the recommendations, you can get a bathhouse, the communications of which will serve faithfully for many years, and will not require intervention, repairs or significant alterations.

Anyone who has ever installed a bathhouse in their home knows that its system requires a good sewage system. And those who are faced with the construction of a bathhouse for the first time need to know how to properly install and equip a sewer system for a bathhouse so that it functions without failures.

To do this, it is very important to know how to properly make a drainage drain, what the soil on the site should be like so that it absorbs water well, in which cases you can install an additional bathroom for a bathhouse, where the drainage hole should be located, how many people the bathhouse can serve in one sitting, and others moments.

When building a bathhouse and arranging its sewage system, you need to know certain stages of the work, as well as some rules and features of such construction.

To arrange a water supply or a water supply system that forms one network with sewerage in communications, it is most convenient to use SNiP 2.04.01-85 “Internal water supply and sewerage of buildings.”

When guiding such building codes and the rules, it will not be difficult to carry out work on installation and installation of sewerage in a bathhouse.

In order to choose what type of sewer system to build for a bathhouse, you need to take into account some nuances that will allow you to equip the sewer system in the best possible way:

  • the type of soil composition where the bathhouse is supposed to be built;
  • what is the depth of soil freezing in the area where the bathhouse will be located;
  • what should be the parameters and frequency of use of the bath;
  • whether there is a city or autonomous sewerage main on the site;
  • how probable are the possibilities of connecting the bath sewerage system to city sewer networks;
  • what should be the design of the bathhouse?

Regarding the composition of the soil, it is necessary to remember that highly absorbent soil compositions are most desirable for arranging sewerage for a bathhouse.

These compositions can be loose soils:

  • sandy;
  • crushed stone;
  • silty sands or sands of varying sizes with soil;
  • coarse gravel, boulder or pebble.

If in the area where it is planned to build a bathhouse, there are just such soils, then to arrange a bathhouse in such an area it is necessary to build a drainage well, which will cope perfectly with the water coming from the bathhouse and, at the same time, will be perfectly absorbed into the soil.

Important! However, if the soil in the area where the bathhouse is to be built has a clay composition, then a drainage well is not suitable.

In the case of poorly absorbed soils such as clay, sandy loam and loam, it is necessary to make a pit under the sauna drain where the used water will drain.

Indicators of the average depth of soil freezing for central Russia are presented in the classic table, which is successfully used by most designers, engineers and construction companies:

Photo: indicators of average soil freezing depth for central Russia

All calculation schemes for designing a sewage system for a bathhouse should always be drawn up and calculated based on the depth of soil freezing in a particular area where it is planned to use the site for building a bathhouse.

Important! This must be done in order to avoid damage to the system due to freezing of drain pipes, sedimentation tanks or sauna drainage.

Many experts, instead of a table, prefer to use a map, which also indicates the depth (mm) of soil freezing in a particular territory of Russia.


If you plan to arrange large bathhouse, where a large number of people must be served at once, then it is necessary to provide it with a sewerage system that could normally withstand burst discharges of large volumes.

Drainage wells, pits or septic tanks must be of impressive size, capable of providing high efficiency for wastewater treatment or its effective settling and removal outside the site. Therefore, everything here also needs to be carefully calculated.

When building a small and medium-sized bathhouse, you should also not ignore the following calculations:

  • how many people is the bathhouse designed for?
  • what are the expected volumes waste water will flow from the bathhouse into the sewer;
  • what size should the entire building be;
  • what size should a drainage well or septic tank be?

In addition, a very important point when planning the construction of a bathhouse with individual sewerage will be to take into account the type of bathhouse itself sewer system:

  • non-pressure;
  • pressure;
  • part of the central city sewer system.

A free-flow, or gravity, sewerage system for a bathhouse is a pipeline system through which the water used in the bathhouse flows by gravity into containers, septic tanks, tanks, or where the water settles or is subjected to biological treatment, and then, also purified by gravity, flows into the ground or reservoirs.

It makes sense to equip this type of sewer system when the terrain and area of ​​the site allows for natural slopes when laying pipes (0.20 mm per 1 linear meter of pipeline towards the sewer receiving tank), and also, groundwater lies below the level of any drainage sewer device.

Installation of a sewer system of this type is always economical and practical because its installation requires the least amount of money to be spent on purchasing sewer systems, septic tanks or drainage wells, and there is also a minimal use of labor.


Photo: pressure sewer system for a bathhouse

A pressure sewer system for a bathhouse is already different in that it is not as energy independent as a non-pressure one.

After all, if in the first case water enters the sewer system by gravity, then when installing a pressure sewer system, sewer pumping units must be installed.

The pumps that are equipped with the pressure sewer system in the bathhouse must pump out wastewater and supply it not only to the pipeline, but also to a pit or septic tank, where the wastewater will undergo treatment, purification and forced (again, using a pump) release of treated wastewater into soil or storage containers.

Important! It is advisable to install such systems in cases where the groundwater level is high enough, the area personal plot too small or the bathhouse is located in ground floor private residential building.

Such sewer systems are least likely to become clogged by hair rolls or accidental ingress of soap into the pipeline because, under the pressure created by the pump, these inclusions, along with wastewater, are very quickly fed into a septic tank, sewer tank for cleaning or storage well.


Photo: sewer tank for cleaning or storage well

Bath sewerage, which can be connected to the central city sewer system, has the most profitable option for bathhouse owners.

After all, you won’t have to deal with wastewater treatment yourself because all of it will end up in the central sewer lines, therefore the collectors, and then from there to the city treatment plants.

The only difficulty that may arise here is the installation and insertion of sewer pipes going from the bathhouse to the central system.

Difficulties may also arise when preparing documents to coordinate work on insertion and connection with government agencies, responsible for the city's sewerage networks.

Others no less important points When organizing and arranging sewerage for a bathhouse, its construction and the presence of an additional bathroom can be used.

By and large classic options Bath devices in their design have the following premises:

  • bathroom is a must;
  • shower - installed so that you can wash yourself;
  • dressing room - it is equipped with either benches and a table for snacks, or a font with cold water;
  • steam room - the actual room where you steam.

Photo: steam room

All these premises must be equipped with a drain because they, to one degree or another, discharge wastewater into the sewer.

Availability additional rooms, where the used water is also supposed to be drained, should also be taken into account. What is this for?

Suppose you have installed a toilet in your bathhouse, then according to the rules of the SES, you are required to use a septic tank with activated sludge as part of your sewer system, which processes wastewater and disinfects it.

And if your bathhouse is equipped with a bathroom with only a washbasin, but no toilet, then there is no need to install a septic tank with activated sludge.

After all, only soapy water will flow out of such a bathhouse, then it is enough to build a sewer with a drainage well or pit.

Scheme

Before you understand what the sewerage system in the bathhouse should be, you need to decide on the type of sewerage system both indoors and outdoors.

If the soil in your area allows the installation of a drainage well, then the design of such a sewerage system will differ significantly from the design of an external sewerage system for rocky, clay or loamy soils.


Photo: sewerage diagram in the bathhouse

This diagram is the simplest drainage sewer system in a bathhouse, and it is also gravity-flowing, that is, free-flowing. The necessary slopes are very clearly visible here.

Which must be done when laying a pipeline, the presence ventilation duct and exit to the outside, the required depth for a particular section of the pipeline with a difference, and, finally.

A drainage well with a bottom made of gravel, which is a natural filter for sewage.

In the case of rocky, clayey or loamy soils, the absorption of which is very low, a special pit is installed in the sauna sewerage system.

This pit is a storage tank made of any waterproof material from which the drainage pipe, discharging wastewater further from the site.

The drainage of wastewater can be to fields, ravines, reservoirs or rivers. Drains such as bathhouses are not considered too dirty, provided, of course, that there is no toilet in the bathhouse premises.

When arranging a pit, it is very important to properly arrange a water seal, which should limit the entry of unpleasant odors inside the bathhouse.

Also, for the installation of such a sewer system, it will be most effective to use plastic pipes made of durable polymer material, such as polypropylene or polyethylene low pressure.

Important! Sewage pipes for external sewerage are always used with a diameter of 100 mm. The pit is made directly under the floor of the bathhouse, and therefore, first you need to make it right away, and then lay the boards with gaps on wooden joists. The logs are laid on bricks.

A hole is dug in the center of the bathhouse with gentle slopes leading to it. The entire surface is waterproofed with a concrete screed. A drainage pipe should extend from the pit, which will carry the wastewater far beyond the site.

The plate, which is located above the pipe, will form a kind of water seal, so that unpleasant odors will not penetrate into the bathhouse.


Photo: a kind of water seal

The drain pipe of the pit should be located at a height of 10-12 cm from the bottom of the pit. And between the plate and the surface of the pipe there should be a gap of about 5 or 6 cm. The pit can be waterproofed not necessarily with concrete, but you can also use plastic containers for this.

DIY device

What you shouldn’t rush into when building a sewer system for a bathhouse with your own hands is the construction of the room itself. This is especially true for floors. Sewerage for a bathhouse has its own specifics, and therefore there is no need to rush into laying the floors for its premises.

Almost any diagram of internal sewerage in bathhouses shows that communications and devices are located under the floor, and it doesn’t even matter what type of floor is planned to be laid: with gaps between wooden planks or without them.

Moreover, it is very important to think about ventilation system, which could cover all rooms of the bathhouse in its service. If this is not done, then it will be very uncomfortable to use such a device as a bathhouse.

Internal sewerage

If you decide to make a sewer system for a bathhouse according to the old Russian custom, then you will need to dig a hole in the center of the room, which will combine a washing room and a steam room with partitions that separate one room from the other.

If you make the washing room and steam room separate rooms, then you will need to make holes for each of these rooms.

In this case, two drain pipes will come out of the bathhouse, or two connected into one big pipe, which will already be directly laid underground from the outside.

In the same way, you can arrange a sewer system for rooms where there is a swimming pool, toilet or washbasin.

According to the old custom, a sewer system for a bathhouse is made without a pipeline. The pit that is made in the center of the room is called a pit.

Such a pit can still be made close to the bathhouse, and drain pipes coming from the bathhouse premises are connected to it. If the pit is under the floor of the bathhouse, then the floors are made to leak, with gaps between the boards.

Through these cracks in the floor, water flows into the pit, and from it through a drain pipe, it is discharged outside the site.

These designs are very convenient because they do not require special maintenance or care. The most important thing here is to properly make the pit itself and drainage.

Important! If it is necessary to make the floors continuous without gaps, then the pit is made without a concrete screed on floors with slopes. It is enough to make a sealed hole to which a truncated piece of drain pipe will be connected.

It looks like this: The floors are laid at a slope towards the center of the room, where there is a hole. Water flows into this hole and enters a special chute, which discharges the water into a pit, and from there through a drain pipe outside the bathhouse.

Even a flat, continuous floor without a slope can be equipped with such gutters. But then you will need to leave gaps around the perimeter of the room, between the wall and the floor.

These gaps are equipped with gutters like a truncated plastic sewer pipe that is located under the floor and fits tightly to the foundation.

The gutters are installed at a slope towards the pit, where the drain pipe is also located. Through these gutters, water flows into a pit, and from there it is discharged outside the bathhouse.


Photo: water flows through these gutters into the pit

If you are satisfied with the option of a floor with cracks, then you dig a hole that will be under the floor of the bathhouse, then make a cement or concrete screed.

Moreover, the screed needs to be done not only of one hole, but also of the entire space under the floor. This surface under the floor must be concreted with a slope on all sides towards the pit.

There are no gutters here anymore, and therefore the corners between the wall and the future floor can be reliably sealed with some rolled waterproof material, such as roofing felt, and on the side of the surface that will be under the floor of the bathhouse, you can safely fill it with a concrete screed.

Important! Don’t forget to also attach a drain pipe, which is best placed at a height from the bottom of the pit somewhere from 10 to 12 cm.

Above the pipe, attach a special plate to the fastening fittings (anchors, studs, nails), which will block unpleasant odors, thus preventing the penetration of unpleasant odors of standing water into the room.


Photo: a plate that will block unpleasant odors

There is another convenient option for installing sewerage in a bathhouse, this is an insert into the pipeline of the central city sewerage system, which is available in the house.

Here you will need the same amount of effort as it was required to arrange a sewer system when building a private house.

Namely: the necessary plastic pipes, sealant, welding machine, if you are welding a pipeline, or couplings, flanges, fittings and other connecting elements for pipes.

In this case, in all rooms of the bathhouse where used water is discharged through any plumbing or structures such as a swimming pool, etc., you lay pipes under the floor, to which you connect either the plumbing, or the pool drain, or a gutter from the floor in a steam room or washing room.

Important! All these pipes do not need to be led to a septic tank or drainage well, because you have an inlet pipe for this purpose, through which all drains will flow into the central sewer system.


Photo: Underfloor piping system

If you do not have the opportunity to connect to the central city sewer or install a pit, then you can also use a pipeline system under the floor, but only with drainage to a drainage well.

In the case of a drainage well, in principle, you can use a pit, which will be located under the floor with gaps, and the wastewater will simply be discharged not into fields, reservoirs, rivers or ravines, but directly into a drainage well with a filtration bottom made of expanded clay.

Whatever sewage system you choose inside the bathhouse: with or without a pipeline, but with a pit, in any case you will have to take care of where the wastewater from the bathhouse should be discharged.

Important! You should also study all the recommendations and advice of experts, which cover not only the standard procedures for installing an internal sewerage system in a bathhouse, but also the features and specific points that apply exclusively to the arrangement of sewers in bathhouses.

  • in the process of connecting plumbing or drain points to the pipes in the bathhouse, you need to install a water seal at each such point so that unpleasant odors do not penetrate into the premises. For plumbing, water seals are created using siphons, for a pit using a special plate, for a pipeline going to a drainage well, it is allowed to use a pipe slope that will be equal to or greater than the diameter of the pipe itself, and for a pool a siphon will also be sufficient;
  • when laying any pipeline in a bathhouse, it is necessary to take into account high temperatures, and therefore use building materials made of durable and heat-resistant plastic or any other material;
  • pipe slopes should be no less than 2-3 mm and no more than 15 mm per 1 linear meter pipes;
  • if there are places where several pipes are connected, then inspection wells should be installed there to make it easier to clear the sewer from blockages;
  • all valves, mixers or shut-off valves must be made of non-flammable and non-melting materials. It is also advisable to use door handles, towel racks, shelves for detergents and personal care products made from materials with low thermal conductivity;
  • all drain holes in the floor of the bathhouse rooms must be protected with nets that will prevent leaves from brooms, hair and other debris from entering the sewer system that could clog the pipeline;
  • It is advisable to place all valves and taps as low as possible, close to the floor because the temperature there will not be so high;
  • the pipeline must not be laid close to heating devices, fireplaces or sauna stoves;
  • the pit must be located at certain distances from various objects.

The pit must have certain parameters:

  • location from the foundation of the building by 50 cm;
  • pit depth is about 70 cm;
  • cross section – 50 x 50 cm;
  • covering with a layer of concrete – 10 cm;
  • location from the drainage well is at least 2.5 m.

External sewerage

Central city sewer lines do not relate to the arrangement of sewerage for a bathhouse with your own hands, and therefore there is no need to consider them.

The only thing that is important to study is the construction of an autonomous external sewage system for a bathhouse.

If the groundwater in your area is low enough and will not interfere construction work and operation of sewer systems or installations, then you can safely plan the construction of a drainage well.

To install a drain well, you need to take several steps:

  • dig a pit no closer to the bathhouse than 3-4 m. Determine the size of the pit yourself, based on the container without a bottom that you have (reinforced concrete rings, plastic containers or masonry brick walls). The depth of the pit should be below freezing of the soil, if, for example, it is 70 cm, then the pit should be dug 1.5 m deeper;
  • trenches for the drain pipe are also dug, which should be dug to a depth below the freezing depth of the soil in your area. For example, if the soil freezing depth is 70 cm, then trenches should be dug 50 cm lower;

Photo: trench for drain pipe
  • the bottom of a pit lined with bricks or a container without a bottom must be lined with a layer of crushed stone or any other filter material. The layer must be no less than 20 cm high and no more than 50 cm high;
  • all pipes that are laid in trenches must be laid on a bed of sand, 10-15 cm high, and then sprinkled with a crushed stone or sand layer, which together with the laid pipe gives 40 cm in width and 40 cm in height;

Photo: pipes are laid on a sand bed
  • if you are installing some kind of container without a bottom, then its outer walls should also be sprinkled with a dry mixture of sand and cement, lightly tamping;
  • a ventilation pipe must be attached to the well, which must be on the surface of the earth at a height of no less than 60 cm;
  • Before filling the soil, the drainage or drainage well must be covered with a lid or ceiling with sewer hatch. The cover or sewer hatches are not covered with earth because it technical part drainage well, which must be opened regularly to provide free access to clearing the well from accumulated sediment.

External sewerage for a bathhouse also includes the installation of a septic tank on the site, to which sewer pipes coming from the bathhouse are connected. A septic tank is necessary if the bathhouse has bathrooms.

After all, wastewater containing feces is already considered dirtier than just soapy water from washing or taking a shower.

The principle of operation of a septic tank is such that it effectively cleans wastewater with various inclusions, and therefore, if there is a toilet in the bathhouse, it is most advisable to install a septic tank.

It can be factory-made, already manufactured as a ready-made system, which includes a sufficient number of chambers and all kinds of devices for wastewater treatment. You can also install a septic tank on the sanitary area yourself.


Photo: septic tank for a bathhouse

For this you can use any containers - from reinforced concrete structures to plastic containers or used car tires.

If the structure is light in weight, then it should be “anchored,” that is, attached with special cables to a concrete platform at the bottom of the pit. But if the structure is heavy enough, then this is not necessary.

For lightweight structures, the outer walls of sewer tanks or septic tank systems are sprinkled with the obligatory filling of water in the container.

The filled water should exceed the sprinkling level by 1/3. If desired and if there is such an opportunity, an additional filtration well can be installed to the septic tank, which will serve as wastewater tertiary treatment.

Important! This is especially interesting for those who plan to use purified water for irrigation of gardens or fields, or for technical needs.

Video: laying pipes and sewers

Ventilation in the bath

In order to properly arrange the ventilation system in the bathhouse, in order to avoid tragic cases, you should familiarize yourself with the circulation diagram of hot steam and temperature in the bath.

For those who have not thought about temperature fluctuations in a bathhouse during a steam room, or have forgotten from school physics lessons, let us remind you that the highest temperatures are at the top, and the lowest are at the bottom.

Thus, the ventilation hole with an exit pipe should be made at the top of the steam room. And in order for fresh air to enter the room, it is necessary to make a hole at the bottom, almost near the floor.

Those openings that are located under the ceiling are called exhaust (pulling excess steam out), and those near the floor are called supply (inflow of fresh air).


Photo: exhaust holes

With proper ventilation, you will not only save yourself from exposure to hot steam, but also protect yourself from carbon monoxide.

The exhaust openings can be equipped with special automatic hatches, which will operate when the air temperature in the steam room reaches a certain point.

In the simplest system, the ventilation holes in the bathhouse are closed with wooden plugs to heat the air in the steam room, and then the holes are opened when it is necessary to provide the premises with clean and hot air in the bathhouse.

How to choose sewer equipment

Sewage equipment for a bathhouse includes the following components:

  • pipes;
  • plumbing;
  • connecting elements and materials;
  • container for a drainage or storage well;
  • septic tanks.

Pipes should be used that are made of heat-resistant materials. These can be either metal or plastic pipe products.

The most commonly used plastic pipes today are made from polymeric materials: polypropylene (PP) or low-density polyethylene (HDPE).

Such pipes can withstand temperatures up to +95% if they are high-quality materials. With low quality, plastic pipes can withstand only +75% degrees.

If you are making internal sewerage for a bathhouse from a pipeline, then take high-quality PP or HDPE pipes.

Important! And if you just need a pipe to carry hot wastewater outside the bathhouse, then you can use plastic pipes that can withstand temperatures up to 50-75% degrees - this is enough to drain the slightly cooled wastewater from the bathhouse outside.

Bathroom plumbing should also only be selected that can withstand hot air.

It is clear that in the steam room there is no plumbing as such, but we should not forget that if the steam room is combined with a washing room and is separated from it only by a small partition, then care should be taken to purchase a rotary shower that is mounted into the wall.

A rotary shower is installed in the wall, covered with a panel and delivers only jets of water, and therefore using such a shower in a bathhouse is very convenient and even safe because there is no risk of getting burned metal surface souls are kept to a minimum.


Photo: rotary shower

For rooms in the bathhouse that are isolated from the steam room, you can use regular plumbing fixtures. So for the washing room, which is separated from the steam room, where there is no hot air, you can install a very convenient column shower, which is ideal for the conditions in the bathhouse.

Such a shower is perfectly connected to internal sewerage pipes of a smaller diameter, then the pipes are connected through an adapter to such an important section of the sewerage system in the bathhouse as, thanks to which wastewater from the shower (as well as from other plumbing fixtures and equipment) is transported and supplied to sewerage treatment plants structures.

Photo: column shower

Connecting elements and materials are all kinds of adapters, fittings, turn signals, plumbing silicone and other materials with which plumbing fixtures are connected to the sewer pipeline in the bathhouse.

Important! Sealant or plumbing silicone must be present, because they provide enhanced sealing of connections between plumbing fixtures and pipes or pipes between themselves.

The entire system must be sealed and not leak, otherwise you will constantly have all sorts of discomforts in the bathhouse.

Sewer sanitary equipment for a bathhouse should also include septic tanks, which are used, as a rule, for autonomous (individual) sewer systems.

The principle of operation of the septic tank is such that, receiving wastewater in the first chamber, it purifies it using biological mass (anaerobic or aerobic bacteria, depending on the septic tank model) in activated sludge, where the wastewater is processed and converted into sludge and water.

The water in the first chamber thus settles, accumulates, reaches a certain point and enters the second chamber, where the next stage of wastewater purification occurs.

Depending on the model of the septic structure and the devices it contains, the second stage of wastewater purification can occur under the influence of aerators that supply air flows into the water.

If there are no such devices, then the wastewater also settles and flows into the next chamber, either a filtration well or fields. At the last stages, the water is purified by almost 95-98%, which is considered high degree cleaning.

Thus, all the water used in the bathhouse, plus, if there is a toilet, is cleaned and can be safely taken out to the fields, used for irrigating lawns, gardens and vegetable gardens, and even used for economic and technical needs.

Features of flooring

The flooring in the bathhouse has several options for laying it:

  • leaking leaky floor;
  • capital self-leveling floor;
  • continuous sloping floor lining with gutters.

The arrangement of the sewage system in the bathhouse directly depends on the type of laying of boards on the floor or self-leveling concrete screed.

Leaky and non-leaky floors

Leaky floors include leaky floor structures that allow used water to bath procedures drain freely into a pit equipped under the floor.

The design of such floors is such that the boards, which are laid on wooden logs, which, in turn, stand stably on small brick racks, are laid with a small gap between each other - about 5 mm.


Photo: flowing fields

Leak-proof floors include both a self-leveling concrete floor and a wooden floor with boards tightly adjacent to each other.

The advantages of concreting floors are their strength and aesthetics in terms of decorating materials, such as tiles, for example.

All leak-proof floors are equipped with a slope towards the drain hole, where the drain pipe is located. Such floors are made first, after the walls and roof.


Photo: drain hole where the drain pipe is located

For lovers of everything natural and natural, a solid bath floor with tightly fitting boards is suitable. Here it is also important to take into account the slope towards the hole where the used water should flow.

Such floors can also be equipped with gutters along the walls, instead of a drain hole in the middle of the washroom or steam room.


Photo: solid bath floor with tight-fitting boards

If the floor is leak-proof, then a protective grill must be installed for the drain hole, which does not allow the sewer system to become clogged with leaves of bath brooms or skeins of hair.

How to arrange a manhole for communications

Inspection wells in sections of sewer systems for bathhouses are installed in cases where the length of the external sewer system is more than 10 meters.

Also, reasons for equipping sewerage with inspection wells include pipeline branching. It is in the areas where pipes are connected, where they turn and where there are differences, that it is necessary to install inspection wells.

Important! Wells of this type are needed to regularly check pipes for blockages and, if necessary, to carry out timely cleaning of sewer pipes.

There are accepted standards and the distances that are permissible between manholes on an extensive sewer route. These norms of permissible distances depend on the diameter of the pipes that are used for laying external sewers.

For a bathhouse, as a rule, sewer pipes with a diameter of no more than 155 mm are used, and therefore the permissible installation distances for inspection wells should be at least 35 m.

Such wells can be either concrete rings through which sewer pipes pass, or plastic wells-turners or adapters, which are built into the pipes as their addition.

Concrete structures perfectly protect the most vulnerable sections of the pipeline, and also provide full access for the repairman to go down into the well and check the sewer pipes for blockages.

Important! Such wells must be equipped with a ceiling and a cover or manhole. This must be done to prevent people from getting into the well. precipitation or garbage.


Photo: installation of a manhole

When installing a reinforced concrete inspection well, it is necessary to use a grinder to make holes where the pipes will pass through the reinforced concrete ring. Then lower the ring into the trench widened for the well.

Therefore, pass the pipes through the well so that the pipe connections are inside the ring. Tightly seal the joints of the pipes and the surfaces of the walls of the concrete ring, and then sprinkle the outer walls of the reinforced concrete well with a dry mixture of sand and cement (1:1).

The linear type of inspection well is installed where the section of the external sewer pipeline is straight, and the rotary type is installed at the corners and turns of the sewer line.

There are also plastic inspection wells, which are much easier to install, and they last much longer than reinforced concrete products, which are regularly sprinkled.


Photo: plastic inspection well

It is easier to install such wells because they are lightweight and even one person can handle them during installation. In addition, most models of such wells are made with already built-in sealed pipes for connecting pipes of various diameters to the well.

And this, you see, already eliminates an impressive piece of work. Installing such a well is a pleasure. During installation, it is also necessary to sprinkle the outer walls of such a well with a dry mixture of sand and cement for a more durable installation.

For any scheme and project for equipping a bathhouse with a sewer system, it is necessary to use clearly planned methods and technologies.

Just as before, classical technologies from those times that our ancestors used when arranging Russian baths on their property are suitable. Modern technologies can also be applied no less than old ones.

Important! The most an important condition When installing and laying a sewer system for a bathhouse, it is important to correctly fulfill all the requirements and recommendations for drainage, drainage, ventilation, and wastewater treatment.

If all precautions and rules are followed, then your bath sewer system will always work at the highest level.

Video: do-it-yourself sewer

The place that the bath procedure occupies in Russian culture and everyday life is difficult to overestimate. And it is quite clear that one of the first buildings on any suburban area In our country, a bathhouse is installed almost simultaneously with housing. However modern baths They have gone quite far in their perfection from those buildings in which our ancestors loved to steam.

Of course, even today you can often find bath houses into which you have to manually carry water from a well, a pump, or simply from a river, and they can only be heated with wood. However modern people have already become accustomed to comfort in all areas of life, so various engineering communications in a bathhouse today are almost a mandatory attribute.

Yes, many fans of steam and brooms appreciate the very process of preparing the steam room for the bathing ritual, receiving true pleasure from chopping wood, heating the stove or carrying buckets of water. But still, most of us are accustomed to value our time and do not like to make unnecessary efforts. Therefore, it will not be superfluous to find out what kind of communications are needed in a modern bathhouse, about the features of their installation, as well as other important nuances.

In many ways, the set of communications that need to be connected to the sauna house is determined by local conditions. In particular, the presence or absence of centralized utility networks nearby.

However, you can create a kind of “gentleman’s set”, without which it will not be very convenient to use the steam room:

  • (from a centralized water supply network, artesian well, from the nearest reservoir or well). Water is the only thing without which you can’t wash or take a steam bath. It’s good if the steam room is designed for 2 people. What if it's ten? Then you will have to carry water manually all day. After all, even for an ordinary family of 3 people you will need at least 100 liters of hot water alone. And how will you be able to wash yourself normally if you have to constantly wonder whether there is enough water for this?
  • (either connected to a centralized power supply, or from a generator of any type used today - windmill, diesel or gasoline generator, etc.). Steaming by candlelight is not only inconvenient, but also unsafe. Even kerosene lamps do not guarantee good lighting. Therefore, electricity is necessary at least for the operation of lighting fixtures.
    If the water supply is from a well, standpipe or river, then the pump that pumps the water will also most likely be driven electric shock.
    Often in the rest room there is a TV, a stereo system, and there is probably an electric kettle or an electric samovar. And given the popularity of heating elements for heating and the widespread use of electric boilers for heating water, then supplying electricity to the bathhouse is a necessity.
    However, this will require obtaining permission from the relevant authorities. Carry out the installation extremely carefully, following all the rules. Electric current and high humidity- a very dangerous combination.

  • Sewerage. Of course, in principle, you can do without it or limit yourself to the simplest drain. However, with this approach, very quickly the area around the bathhouse building will become swampy, and the remains detergents, contained in the plum, are unlikely to have a beneficial effect on the ecology of the site. A toilet in the bathhouse will also be absolutely useful. Running in the middle of a bath procedure when necessary to a booth in the yard or to a residential building is not very pleasant. Therefore, this rather specific communication for the bath should also be recognized as necessary.
    It is installed in all rooms from which waste water can flow - in the steam room, washing room, etc. Typical schemes autonomous sewer systems required bandwidth You can find out from specialist plumbers.
  • Ventilation is an absolutely necessary system, and its installation requires competent preliminary calculations made by professionals. Ventilation is necessary both for the health of visitors to the bathhouse and to extend its service life: high humidity does not benefit the materials from which the bathhouse structure is built and which are used for its decoration.

A separate issue is the need for eyeliner. Today, they are often used for heating and heating water in bath buildings. gas boilers . Their operation from cylinders, although theoretically possible, is only valid in theory. In practice, you will need a branch from the gas main, if possible. Well, if not, then the problem simply disappears by itself.

These are, perhaps, all the main communications in the bathhouse, which ensure its visit and full use without additional hassle.

Laying communications

If the owner of a bathhouse is “hands-on”, he can do a significant part of the work independently.

Perhaps it is better to invite professionals only for sewerage and electrical wiring.

All the nuances should be thought out in advance, the required amount of materials, including consumables, should be calculated, and the necessary tools should be selected. To avoid unpleasant surprises later, already during the work on laying communication in the bathhouse, a scheme for carrying out with all important details must be prepared in advance.

It is clear that it is better to deal with the eyeliner during the construction period and include a communications plan in the overall project. However, it is quite possible to modernize an already built bathhouse to the desired condition. It is clear that in this option, it is necessary to competently plan the entire work process in advance, and not do things “by eye.”

Of course, after weighing all the pros and cons, many will agree that communications in a modern bathhouse are certainly necessary. But which ones exactly will be determined by specific conditions and depend on the financial situation of the owner of the bathhouse and the availability of technical capabilities.

The bathhouses of our ancestors did not have communications. The furnace was done “black”; nearby there was a well with water, and next to it a cesspool. Today everything has changed significantly. Steam rooms are built from the most different materials, these are: unplaned timber, log house, profiled timber, rounded log, laminated veneer lumber, frame technology– and for each type of bathhouse it is necessary to connect all known communications.

What do we need?

Even at the construction stage, the bathhouses provide for the supply of the necessary networks. This is electricity, water, gas, if installation is planned gas boiler, sewer or wastewater system. Please note that electricity in the bathhouse is used not only for lighting, but also for connecting electrical appliances and an electric oven. Heaters or gas boilers are also often used. The water supply from the well is carried out by a pump, which also runs on electricity. Modern bathhouses often have heated floors. In addition, you need to drink tea, listen to music and much more. To connect a bathhouse to the electrical network, you must obtain permission, and the electrical wiring and devices themselves must be laid in accordance with certain requirements and standards.

We supply water

When building a bathhouse, they think about the water supply, because one of the main tasks is hygienic, so the presence of hot and cold water a must in the bathhouse! Without this communication, it will not be possible to simply wash yourself. The main sources are centralized or autonomous systems, alternative option- well. If your bathhouse is located in your country house, then it is better to make an autonomous water supply or a well, since central system water is supplied with frequent interruptions. A well with water is quite suitable for a small bathhouse. You can also install storage tanks large volume, where you can pump water at any time and use it without hindrance.

To prepare hot water you will need an electric boiler or gas boiler. Sufficient water exchange for washing an average family is 100 liters. Electric option allows you to heat water very quickly and apply it immediately. The water heater has a permanent connection diagram, so any number of visitors can wash. The only drawback is that increased energy consumption is not always cost-effective. Installing a gas boiler is a labor-intensive process and can only be carried out by certified specialists, but in the future this means good savings on water supply.

Installation of the water supply system is made of metal-plastic or polypropylene pipes. Fittings are used to connect elements. Cold and hot water will allow you to wash yourself after meals and carry out heating procedures. A shower is a more convenient way to wash than a bucket of water. In addition, this is an excellent system that saves space. There is no need to install benches for washing. A little advice– in order not to disturb the hygienic environment in the steam room and washing room, be sure to wash all shelves and benches with plenty of water after eating and washing.

Hot water can be obtained more in an economical way than installing a gas or electric boiler. This is the arrangement of a circulation system through a special pipe, which is located in the chimney of the stove. The water circulation is carried out by a pump.

Making a sewer

Sewerage– a mandatory communication system for any bathhouse. This is not only a toilet, but also a drainage system. If you do not have a central system, then it is enough to equip a cesspool or septic tank ( modern system sewer cleaning). It is possible to do the work yourself. This is a small water intake well. To install the system, special pipes and a water seal are laid in the floor, through which water flows into a collection container. The septic tank is filled with a special composition. Bacteria decompose feces, reducing the volume of waste tenfold. The water settles and fits into the soil. Drain ladders are installed in the steam room, washing room and toilet. The trap is a special water seal that reliably “locks” odors in the pipes, preventing them from entering the premises. A grill must be installed on it, which protects the system from clogging the sewer with leaves. In the steam room, a threshold with a height of 15–20 cm must be built, so the feasibility of arranging a spillway is obvious.

Septic tank is enough simple system, which can serve without repair and maintenance for a long time. However, this system is not suitable if the groundwater level is higher than 2 m. If this level exceeds the specified limits, then the installation of a sealed container is required, from which water and waste are pumped out using vacuum trucks. Sewage, which is done according to all the rules, allows you not to experience any discomfort when visiting the bathhouse. You just need to do everything in strict accordance with the recommendations of specialists.

Wiring electricity to the bathhouse

The laying of electrical wiring in the bathhouse is given special attention. In fact, only the part that goes directly into the steam room requires special treatment. This room has special conditions - high humidity and temperature. You need to start laying from the main lighting panel, in which a separate automatic circuit breaker and an RCD are installed in the bathhouse (the protection will prevent the possibility of electric shock). The ratings of circuit breakers, RCDs and wire cross-sections are selected individually depending on the number of electrical equipment and the power of the luminaires.

If you only have lamps, the wire cross-section and ratings of circuit breakers are taken to the minimum; those designed for a current of 16A are sufficient. Many have additional equipment, a refrigerator, electric heater perhaps a pump. In this case, a specific approach and calculation of the consumed load is required and, accordingly, selection of the input circuit breaker and cable cross-section.

The wiring in the dressing room is no fundamentally different from the same as in a regular house. The only difference is the wood trim and the corresponding wiring - external in a corrugated pipe. The elements are fastened to the walls using special brackets. The location of sockets and switches is selected individually, the accepted distance from the floor to the switches is 150-170 cm, from the floor to the sockets - 50-60 cm. The distance of horizontal wiring from the ceiling along the wall is 10-20 cm. The light in the dressing room can be any, you can hang a regular chandelier with incandescent lamps. It is advisable that the lamps be protected by shades from below. If the bulb breaks, the glass will not fall on the floor and the likelihood of cuts will be reduced.

Separately, it is necessary to consider the wiring and lighting in the steam room. Lamps must be chosen IP44 class. The lampshade should be glass and the body metal. Plastic elements may become deformed due to high temperature. For wiring, it is advisable to use wire of the RKGM brand. It is able to withstand temperatures ranging from -60 to +180 degrees for a long time. It is especially worth noting that neither switches nor sockets can be placed in the steam room. All this is placed in adjacent rooms, and the ends of the wires to the lamps located inside the steam room should be as short as possible and without additional connections.

Long gone are the unsightly bathhouse buildings with the random flow of dirty water into “nowhere” or the nearest body of water. Today, sewerage in a bathhouse is not a luxury, but a necessity. The installation of a high-quality wastewater disposal system is prompted not only by ethical and aesthetic standards, but also by legal requirements aimed at ensuring environmental safety environment.

The first step to improving the bathhouse is assessing the condition of the soil on the site, determining the optimal depth for laying pipes and deciding on the location of the septic tank. It’s easiest for those homeowners who were directly involved in the construction of the bathhouse or built (are building) it themselves. It is no secret to them the type of soil, its freezing point (FFP) and groundwater level (GWL).

Without knowledge of these indicators, it is impossible to build a trouble-free sewer system. For those who purchased a plot with a bathhouse built on it, you will need to perform a set of simple observations and calculations.

To determine the type of soil, you can conduct an express study that does not require special knowledge and is based on visual inspection and tactile sensations. For this purpose, in the proposed pipe laying location, a hole is dug with a depth of 25-30 cm below the TPG. Information about the depth of soil freezing in a given area can be obtained from neighbors, from reference books, and on specialized Internet resources.

RegionsSoil freezing depth, cm
Vorkuta, Surgut, Nizhnevartovsk, Salekhard240
Omsk, Novosibirsk220
Tobolsk, Petropavlovsk210
Kurgan, Kostanay200
Ekaterinburg, Chelyabinsk, Perm190
Syktyvkar, Ufa, Aktyubinsk, Orenburg180
Kirov, Izhevsk, Kazan, Ulyanovsk170
Samara, Uralsk160
Vologda, Kostroma, Penza, Saratov150
Voronezh, Perm, Moscow, St. Petersburg, Novgorod, Ryazan, Tambov, Tula, Yaroslavl140
Volgograd, Kursk, Smolensk120
Pskov, Astrakhan110
Belgorod, Kursk, Kaliningrad100
Rostov90
Krasnodar80
Nalchik, Stavropol60

It is important to take a soil sample at the bottom of the pit, since sewer pipes will be laid at this level. After which the soil sample is carefully examined visually, rubbed between the palms, and rolled into a rope.



And they evaluate the results according to the table.

If it turns out that the soil is clay or loam, you should know that these categories of soil are classified as highly heaving. In this case, the pipes will need to be laid on a sand “cushion” by analogy with “floating” foundations. The sand will act as a shock absorber during seasonal soil movements and the integrity of the underground part of the sewer system will not be compromised.


After the safe depth for laying the pipeline has been determined, the issue of the location of the septic tank (filtration well) is resolved. The wastewater collection point must be separated from the water intake point by at least 15 m and located no closer than 7 m from the foundation of the bathhouse.



Choosing the type of sewer system

To improve the bathhouse, it is possible to use three types of individual sewerage:

  • non-pressure;
  • pressure;
  • connected to a centralized city drainage system or to the existing sewer system of a private house.

Gravity system

The non-pressure method of drainage is otherwise called gravity. This is the simplest and least expensive type of sewage system for a bathhouse. Its main advantage: energy independence. Installation of a free-flow system requires careful adherence to the slope of the pipes (1-1.5 cm per 1 linear meter) and is impossible if the terrain of the site is difficult.

To transport wastewater, pipes of a larger diameter are required than when installing a pressure system. Straightness of the highway is highly desirable. If the pipeline diagram includes turning points, inspection wells are installed in these places. This rule is relevant for any type of sewer system.


Gravity sewerage – PP pipes



Pressure system

The pressure sewer system provides for the forced transportation of wastewater, which is provided by a pump or pumping station. The equipment can be installed both indoors and outdoors. A pressure sewerage system for a bathhouse is built if for some reason it is impossible to make a non-pressure one. Features of this type of sewer:

  • pressure is more expensive than non-pressure;
  • volatile;
  • requires insulation of equipment in winter.

Pressure sewerage – pumps



Inset sewerage system

A less labor-intensive, but most troublesome way is to connect to a centralized sewer network. This method is not possible for all bathhouse owners. Therefore, it makes no sense to consider it in all details.

More often, it is used to connect the wastewater system to an existing septic tank on the site. However, in this case, you will have to choose the type of drainage system (pressure or gravity).

We design a sewerage scheme for a bathhouse

For greater design convenience, the unified sewer system is divided into two types: internal and external. The first includes communications indoors, the second - outside the building. Once you familiarize yourself with the basic principles of constructing a circuit, it is easy to develop it yourself.

Design stages

  1. It is necessary to draw a plan of the bathhouse, taking into account the thickness of the walls and partitions of the building. Graph paper is best for this purpose, but you can also use a regular piece of checkered paper.


  2. Indicate the dimensions, mark the installation locations of plumbing fixtures or drain points.
  3. Determine the location of the main pipe outlet.
  4. If the bathhouse has a toilet, take into account the need to install a drain pipe.



  5. Along the most convenient and short trajectory, they connect plumbing fixtures to the main pipe, aiming for minimum quantity highway turns.
  6. The length of the communications is summed up, taking into account the outlet beyond the outer wall of the bathhouse.
  7. Proceed to constructing a drawing of the external sewer system.

Rules for designing an external network:

  • an inspection hatch is provided at the junction of the external and internal sewerage;
  • according to SNiP, inspection wells are installed at the turning points of the main line, at the points of connection of a separate side branch of the pipeline, every 15-35 m of a straight main line with a pipe diameter of 100-150 mm;
  • according to SNiP, the slope of external sewerage with a pipe diameter of 110-150 mm is 0.01 (1 cm per 1 meter);
  • the first inspection well should be located no closer than 3 m and no further than 12 m from the bathhouse;
  • if the site has a large slope and there is a toilet in the room, install a multi-stage sewerage system with drop-off wells.





Water seal options

A water seal is an important element of the sewer system, the purpose of which is to cut off unpleasant odors coming from the septic tank (drainage pit). Simply put, this is a water plug that remains in the pipe even if the bathhouse is not in use. An example of the simplest water seal is a U-shaped siphon. In a pipeline made of plastic pipes, a water plug is created using three shaped elements: bends.


Water seal - example

The difficulty is that when the sewer system is rarely used, the water in the water seal tends to evaporate. In this case, experts recommend installing a dry shutter. It is a simple plastic or metal structure, equipped with a spring and a valve (membrane) that blocks the exit from the pipe. When water enters the system, the damper is folded back under its pressure, and after the flow passes, it returns to its place.


Dry water seal - diagram

Craftsmen make unique homemade systems valves for bath drains. If you wish, you can use one of the following options.

System DescriptionIllustration
Into the gap sewer pipe install in a vertical position a plastic funnel with a diameter slightly larger than the cross-section of the pipe, and an outlet with a diameter of 3 cm. A plastic ball (for ping-pong or other) is placed in the funnel of such a size that it blocks the narrow exit. When water gets into the pipe, the ball floats up.

For dry shutter device plastic sewer with a pipe diameter of 50 mm, you will need a 50/110 adapter, which needs to be modified a little: cut at an angle and attach a circle of thick rubber to it. After which the structure is installed at the outlet of the pipe in a septic tank or drainage pit.


Prices for water seal

water seal for sewerage

Which pipes to choose

In fact, the choice of sewer pipes is not so large.

Type of pipesDescription

It is irrational to use cast iron in our time: they are expensive, heavy and inconvenient to install. Ceramic ones are ideal in any respect, but also have a high cost.

Asbestos-cement ones are the cheapest of all possible, but they often disappoint with their defects. In addition, when installing a free-flow sewer system, products with smooth and even walls are required. And asbestos-cement ones have a rough inner surface, often riddled with depressions.

The optimal choice is plastic pipes that are resistant to all types of destructive influences. These products are excellent for installing internal and external sewage systems, are flexible in processing, and are available with or without a socket. The warranty period for plastic pipes is 50 years. For long products, shaped elements (fittings) are offered, with the help of which the sewer system is installed.
  • PVC (polyvinyl chloride);
  • PVC (chlorinated polyvinyl chloride);
  • PP (polypropylene);
  • HDPE (low density polyethylene);
  • polyethylene corrugated.

Any of these products can be safely used in a sewer system. The diameter of the main line is selected based on the expected intensity of operation of the building and the number of drain points. For an average bathhouse with a steam room, washing area and toilet, when installing a gravity drainage system, pipes with a cross-section of 100-110 mm are required. If a toilet is not provided, a diameter of 50 mm is sufficient. Plumbing equipment is connected to the main line with pipes with a cross-section of 50 mm.

Prices for plastic pipes for sewerage

plastic pipe for sewer system

Installation of an internal sauna sewage system

It is necessary to start installing a sewer system at the construction stage of the bathhouse. But it is possible to improve an already finished one, long time exploited building. The scope of work and their sequence are different in both cases, so each option must be considered separately.

Installation of sewerage during the construction phase of a bathhouse

To carry out the work, you will need a previously drawn up plan (diagram) of the sewer system. In order to accurately find the connection points for plumbing elements (drains, showers, toilets, sinks, etc.), markings begin after the foundation has been erected. In places where the main line is laid, trenches of appropriate width and depth are dug.

Important: The bottom of each ditch is leveled taking into account the required slope towards the septic tank.



Then they begin laying the pipes. Experts advise starting the installation of a sewer system by installing the main pipe and large (nodal) elements, to which side branches of a smaller diameter are subsequently connected.

At the connection points, plumbers install vertical pipes. To prevent foreign objects from entering the network, each outlet is closed with a plug. Install the ventilation riser.

In regions with cold climates, pipes are insulated. For this purpose, fibrous materials (mineral wool and its analogues), foam half-cylinders, and foamed polyethylene are used. If desired, you can pre-wrap the pipes with noise-absorbing material, which will significantly reduce the volume of sounds emitted by the operating system.

Lay geotextiles.

Form sand cushion.

Installation of indoor sewage system

If the bathhouse has been in use for more than a year, it can also be equipped with a system for draining dirty water. To do this, you will need to draw up a diagram and open the floor in the right places. The pipes are installed at the foundation level, in one of the walls of which a hole is drilled to lead out the main line.



Drains are installed in the washing room and steam room. When performing work, the following rules are adhered to:

  • the ladder must be located flush with the floor;
  • gaps are closed with moisture-resistant grouts;
  • tiles are laid after installing the ladder.

Prices for drainage ladder

sewer drain

Installation of external sewage system for a bathhouse

Main element outdoor system drainage - septic tank. If the bathhouse does not have a toilet, there is no need to buy a factory product or independently equip a well with multi-level filtration of wastewater. It is enough to dig a drainage hole. But it is relevant only for soils with a high level of moisture permeability (rocky, sandy, sandy loam).

Video - DIY drain hole

Installation of sewerage with a drainage pit

  • According to the diagram, they mark the area: find the location of the wastewater collection point, determine the route for laying the main line;
  • dig a hole 1-1.5 m deep below the TPG;
  • a 20-30 cm layer of sand and gravel is poured onto the bottom;
  • to prevent soil walls from collapsing, you can install a metal container or a column of car tires in the hole large diameter. A more solid structure is a frame built of brick.

They begin to lay the highway. Dig a trench to a depth below the TPG and form a slope towards the drainage hole. Lay the pipes and check that the slope complies with the requirements of SNiP.

At the turning points of the pipeline, inspection wells are installed. In order to prevent pipes from freezing in these places during cold times, it is necessary to provide insulation and cover the holes with double covers.

The place where the pipe enters the drainage pit is sealed using cement mortar or polyurethane foam.

Insulation of the main line is carried out using any in a convenient way: by wrapping pipes with mineral wool or by laying polystyrene foam.

Insulation of the main line

In areas with clay soil To dispose of wastewater, it is recommended to install a pit located under the floor of the bathhouse. The presence of this drainage receiver does not relieve the owner from the need to install an external main that transports water outside the premises. The pit serves as an auxiliary structure for the smooth operation of the sewer system.

A square-shaped pit is dug under the floor with an edge length of at least half a meter and a depth of 1-1.5 m. At a height of 10-15 cm from the floor level, a pipe is installed connecting the pit with external sewerage. Maintain a slope of 1 cm per 1 linear meter in the direction of water drainage. The bottom and walls of the pit are concreted.

Highlights

The owner of a bathhouse must remember that each stage of sewerage installation requires careful compliance with the requirements for it. The failure-free operation of the system is ensured by a properly designed scheme and exact compliance of the pipe slope with SNiP standards. A comfortable stay in the bathhouse is guaranteed by the presence of a hydro- or dry seal.

You should not neglect the design of the ventilation system, as it forms optimal air exchange and promotes the removal of moisture after bath procedures. This will help prevent the formation of mildew and mold. For regions with cold climates, it is extremely important to perform high-quality work on insulating the sewer system.

Video - Do-it-yourself sewage system in a bathhouse

Video - Draining water in a bathhouse with a water seal system

Video - Draining a bathhouse. Scheme

Share